Double-eccentric design for easy opening and increased service life
When constructing butterfly valves, a distinction is made between three main designs.
In a concentric design, such as the GEMÜ Victoria series, the pivot point is in the centre of the seat valve, i.e. the main seal is interrupted by the shaft.
In a simple eccentric construction, the main seal is offset to the shaft axis. There is no interruption over the entire 360° sealing circumference with this design.
In a double-eccentric design, the shaft axis is additionally, as the second eccentricity, moved out of the piping axis so that the shaft centre is slightly offset from the piping centre.
Further features of the GEMÜ R470 Tugela butterfly valve are the shaft blow-out protection as an additional safety measure in case the shaft breaks and the improved sealing due to an optimized disc design in spherical form. The GEMÜ R470 Tugela also has an antistatic spring for use in ATEX areas and a TFM seat ring which is particularly low-brittle and ensures reliable use in a wide temperature range.