The measurement and I/O signals can be assigned to four data memories (RAM data buffer) with different configurable data rates. The data memory is 500 MB dynamic, static about 4 GB and is over USB (up to 1,000,000 readings / second) or SD card expandable. According to the configuration of up to 4 data loggers carried the storage of the buffer data on a selectable medium, such as internal Flash, USB or SD card with selectable logging rate, storage duration, start and stop trigger (auto start condition, touch) with or without pre-and post-trigger.
By separating the real-time function and user function of the controller (real-time kernel, user kernel) ensures that on the one hand sophisticated high-speed tasks such as the dynamic logging of measurement data or fast control of processes, stable and secure be performed and on the other hand users maximum flexibility is offered for own solutions, including the visualization and operation.
Optionally, the test controller Q.station can be equipped with a display (3.5 "full VGA).